A double envelope house is a passive solar house design which collects solar energy in a solarium and passively allows the warm air to circulate around the house between two sets of walls, a double building envelope. This design is from 1975 by Lee Porter Butler in the United States.

History

Lee Porter Butler's 1975 Double Envelope (Shell) design [1] received wide publicity after the U.S. solar energy tax credits were created in 1978. Versions were on the cover of Better Homes and Gardens and Popular Science [2] magazines.

Butler was an artistic/ecological building designer, a self-proclaimed "Ekotect." [3] He did not hold formal qualifications as an energy engineer. Lee had built hundreds of homes, shopping centers and business buildings including banks and schools by the time he entered North Carolina State University to study architecture. He had studied engineering at Georgia Institute of Technology. Lee did not even have a high school diploma, but ended up teaching his invention of "the gravity geo-thermal envelope" at The University of California Berkeley in the Graduate School of design and Planning. Lee went to school for the education, not for the diploma. He was asked to speak at The Royal College of Science in London, where Sir Isaac Newton delivered Principia.

Lee's facile and curious mind led him his entire life to question methods by which humanity could live on the earth in harmony with the earth, and with each other. His most recent contribution to humanity "Ekotecture" is a totally self-sufficient way to live in harmony on the planet and to safeguard human life no matter what the external conditions. Lee felt that if we talk about sustainability we must talk about not just sustaining the earth, but the sustaining of human life. His contributions include a method whereby humanity can live peaceably and safely on the planet in cooperation.

Design and theory

Butler's experimental design was a form of isolated passive solar design that incorporated a passive heat distribution system. It attempted to address the problem of unequal distribution of heat that was associated with some direct gain systems. . This phenomenon is observed particularly in designs with inadequate thermal mass, poor cross ventilation and excessive polar facing windows.[4]

Butler's design essentially composed of a house within a house. Thermal energy was captured from a south-facing solarium and heat was circulated by a natural convection flow loop in the cavity between the two building envelopes and through a sub-floor or via earth cooling tubes.[5]

A recirculating air flow path resulted from the warm (less-dense) air rising in a south-side solarium, and cooler (denser) air falling on the north side to create pressure differentials that automatically moved excess solar thermal gain from the south to the north side of the building without forced convection systems. Air flow was proportional to the differences in temperature between the two convection paths.

In the summer, shading devices eliminate all direct solar gain. Vents are opened at the top to exhaust hot air. Fresh air intake uses ambient temperature Earth to cool and dehumidify replacement air at the base.

In winter, the air in the cavity is buffered by warm ambient-temperature Earth under the floor (which is partially recharged by the natural convection flow loop during each winter day). In the summer, the convective flow is replaced with cooler near-ambient-temperature Earth replacement air, and the warm air exhausts by natural convection.

Criticisms

The original explanation provided for its efficiency was the thermal buffer that existed in the double envelope cavity. However, observers have also commented that the overall insulation of the design is higher with two walls instead of just one.[5]

While the design can perform better than a conventional home, formal performance monitoring suggested there were some problems with the original design. .

Commentators have criticised the design on various grounds:

Subsequent modifications have attempted to address these issues.

Thermal buffer zone house

A modification based on Butler's original design has been described[6] but not yet formally evaluated. It attempted to eliminate some of the initial issues.

An important difference is the northern limb of the convection loop (thermal buffer zone/TBZ) is employed as a utility area e.g. laundry room, closets, pantry, and storage space. The laundry room also doubled as an area for clothes drying.

An external window is located on the north side which can be opened to admit mild air into the TBZ during summer. An additional internal window separates the south side living quarters. This can be opened to admit warm winter air from the solarium to enter directly into northern rooms.

The designer states that on cold winter days, the TBZ tempered with solar-heated air could be often above 85 degrees F, while the outside air was below freezing.

Performance evaluation

Current technology makes it difficult to model the effects of these convective flow designs because computer performance simulation software does not presently incorporate these processes in their calculations.

See also

Passive solar design concepts

Solar-designers