Plasma globe

Not to be confused with Plasma lamp.
A plasma globe with filaments extending between the inner and outer spheres

A plasma globe or plasma lamp (also called plasma ball, dome, sphere, tube or orb, depending on shape) is (usually) a clear glass sphere filled with a mixture of various noble gases with a high-voltage electrode in the center of the sphere.

Plasma filaments extend from the inner electrode to the outer glass insulator, giving the appearance of multiple constant beams of colored light (see corona discharge and electric glow discharge). Plasma globes were most popular as novelty items in the 1980s.[1]

The plasma lamp was invented by Nikola Tesla[2] after his experimentation with high-frequency currents in an evacuated glass tube for the purpose of studying high voltage phenomena, but the modern versions were known to be first designed by Bill Parker.[1] Tesla called this invention an inert gas discharge tube.[3]

Description

The effect of a conducting object (a hand) touching the plasma globe

Although many variations exist, a plasma lamp is usually a clear glass sphere filled with a mixture of various gases (most commonly neon, sometimes with other noble gases such as argon, xenon and krypton) at nearly atmospheric pressure. They are driven by high-frequency alternating current energy at approximately 35 kHz, 2–5 kV.[1] This energy comes from a lower-voltage DC power supply usually connected to mains power, and flows through a high-voltage transformer combined with a high-frequency electronic oscillator circuit which together output a high frequency and high voltage AC to the electrode. Therefore, the circuitry inside the electrode can be considered as a specialized power inverter. The high-frequency high-voltage power, or radio frequency energy, is transmitted into the gas within the globe through an electrode at its center. A much smaller hollow glass orb can also serve as an electrode when it is filled with metal wool or a conducting fluid that is in communication with the transformer output. In this case, the radio-frequency energy is admitted into the larger space by capacitive coupling right through the glass. Plasma filaments extend from the inner electrode to the outer glass insulator, giving the appearance of moving tendrils of colored light within the volume of the globe (see corona discharge and electric glow discharge).

Some globes have a control knob that varies the amount of power going to the center electrode. At the very lowest setting that will light or "strike" the globe, a single tendril is made. This single tendril's plasma channel engages enough space to transmit this lowest striking energy to the outside world through the glass of the globe. As the power is increased, this single channel's capacity is overwhelmed and a second channel forms, then a third, and so on. The tendrils each compete for a footprint on the inner orb as well. The energies flowing through these are all of the same polarity so they repel each other as like charges: a thin dark boundary surrounds each footprint on the inner electrode.

Placing a finger tip on the glass creates an attractive spot for the energy to flow, because the conductive human body (having non-ohmic resistance of about 1000 ohms at room temperature) is more easily polarized than the dielectric material around the electrode (i.e. the gas within the globe) providing an alternative discharge path having less resistance. Therefore, the capacity of the large conducting body to accept radio frequency energy is greater than that of the surrounding air. The energy available to the filaments of plasma within the globe will preferentially flow toward the better acceptor. This flow also causes a single filament, from the inner ball to the point of contact, to become brighter and thinner.[1] The filament is brighter because there is more current flowing through it and into the 150 pF capacity, or capacitance, presented by an object, a conducting body, the size of a human. The filament is thinner because the magnetic fields around it, augmented by the now-higher current flowing through it, causes a magnetohydrodynamic effect called self-focusing: the plasma channel's own magnetic fields create a force acting to compress the size of the plasma channel itself.

Much of the movement of the filaments is due to heating of the gas around the filament. When gas along the filament is heated, it becomes more buoyant and rises, carrying the filament with it. If the filament is discharging into a fixed object (like a hand) on the side of the globe, it will begin to deform into a curved path between the central electrode and the object. When the distance between the electrode and the object becomes too great to maintain, the filament will break and a new filament will reform between the electrode and the hand. (see also Jacob's Ladder)

An electric current is produced within any conductive object near the orb. The glass acts as a dielectric in a capacitor formed between the ionized gas and the hand.

A "Tesla ball" at the NEMO science museum in Amsterdam

The globe is prepared by pumping out as much air as is practical. The globe is then back-filled with neon to a pressure similar to one atmosphere. If the radio-frequency power is turned on, if the globe is "struck" or "lit", now, the whole globe will glow a diffuse red. If a little argon is added, the filaments will form. If very little xenon is added, the "flowers" will bloom at the ends of the filaments.

The neon available for purchase for a neon-sign shop often comes in glass flasks at the pressure of a partial vacuum. These cannot be used to fill a globe. Tanks of gas, each with its specific, proper, pressure regulator and fitting, are required: one for each of the gases involved.

Of the other noble gases, radon is radioactive, helium escapes through the glass relatively quickly, and krypton is quite expensive. Other gases can be used. Molecular gases may be dissociated by the plasma.

History

Video of plasma globe

In U.S. Patent 0,514,170 ("Incandescent Electric Light", 1894 February 6), Nikola Tesla describes a plasma lamp. This patent is for one of the first high-intensity discharge lamps. Tesla used an incandescent-type lamp globe with a single internal conductive element and excited the element with high voltage currents from a Tesla coil, thus creating the brush discharge emanation. He gained patent protection on a particular form of the lamp in which a light-giving small body or button of refractory material is supported by a conductor entering a very highly exhausted globe or receiver. Tesla called this invention the single terminal lamp, or, later, the "Inert Gas Discharge Tube".[3]

The Groundstar style of plasma globe was created by James Falk and marketed to collectors and science museums in the 1970s and 1980s. Jerry Pournelle in 1984 praised Orb Corporation's Omnisphere as "the most fabulous object in the entire world" and "magnificent ... a new kind of art object", stating "you can't buy mine for any price".[4]

The technology needed to formulate gas mixtures used in today's plasma spheres was not available to Tesla. Modern lamps typically use combinations of xenon, krypton and neon, although other gases can be used as well.[1][3] These gas mixtures, along with different glass shapes and integrated-circuit-driven electronics, create the vivid colors, range of motions and complex patterns seen in today's plasma spheres.

Applications

Plasma lamps are mainly used as curiosities or toys for their unique lighting effects and the "tricks" that can be performed on them by users moving their hands around them. They might also form part of a school's laboratory equipment for demonstration purposes. They are not usually employed for general lighting. However, as of recent years, some novelty stores have begun selling a nightlight plasma lamp that can fit into a standard light socket.[5][6]

Hazards

Bringing conductive materials or electronic devices close to a plasma globe may cause the glass to become hot. The high voltage radio frequency energy coupled to them from within the globe may cause a mild electric shock, even through a protective plastic casing. The radio frequency field produced by plasma lamps can interfere with the operation of touchpads used on laptop computers, digital audio players, cell phones, and other similar devices.[1] Some types can radiate sufficient radio frequency interference (RFI) to interfere with cordless telephones and Wi-Fi devices several feet or some meters away.

If a tinfoil hat is placed on the globe, capacitive coupling can transfer enough current through the foil to give a small arc burn or light a small lamp connected to earth ground. This is possible because the globe's glass acts as a capacitor dielectric: the inside of the lamp acts as one plate, and any conductive object on the outside acts as the other capacitor plate.[3] This is dangerous to do, can damage the globe, and presents a fire hazard.[1]

See also

Wikimedia Commons has media related to Plasma lamp.

References

  1. 1 2 3 4 5 6 7 Gache, Gabriel (January 31, 2008). "How do plasma lamps work?". Softpedia. Retrieved November 16, 2009.
  2. Tesla, Nikola (1892). "Experiments with Alternate Currents of High Potential and High Frequency". Retrieved July 26, 2010.
  3. 1 2 3 4 Barros, Sam (2002). "PowerLabs Plasma Globes Page". Retrieved November 16, 2009. |section= ignored (help)
  4. Pournelle, Jerry (April 1984). "The Most Fabulous Object in the Entire World". BYTE. p. 57. Retrieved 2 March 2016.
  5. Plasma Ball Night Light Makes Us Nostalgic For Bed Wetting, gizmodo.com, 2007-11-27
  6. Plasma Night Light, 4physics.com, 2010-02-17
This article is issued from Wikipedia - version of the 10/4/2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.