A stud finder (also stud detector or stud sensor) is a handheld device used to locate framing studs located behind the final walling surface, usually drywall. While there are many different stud finders available, they all fall into two main categories, magnetic stud detectors and electric stud finders.
History
Stud finders have been in use since the early 20th century, and all the first ones were all magnetic, relying on internal magnets to detect the walling fasteners presumably attached to studs. In 1977, Robert Franklin designed a revolutionary electronic stud finder that relied on an internal capacitor to measure changes in density behind the walling.[1] His patent was put into production by the Zircon Corporation, which became the sole producer of electronic stud finders until the patent expired in 1998. While novel, these electronic stud finders did not always prove effective in locating studs.
Since 1998, many developments and improvements have been made to the internal capacitor stud finders and increased their popularity. Recent innovators developed stud finders with multiple sensor plates that sense the wall in multiple places instantly. These sensors can indicate the location, width, and lack of studs simultaneously. With more sensors, these instant stud finders avoid the shortcomings of previous electronic stud finders, which require calibration and do not adapt to inconsistencies in wall construction. While the instant stud finders have made finding studs an easy and efficient task, many people still use magnetic stud detectors.[2]
A few stud finders use ultra-wideband scanners.[3][4] They are based on micropower impulse radar stud detector invented by Thomas McEwan.[5][6][7][8]
Magnetic stud detectors
Magnetic stud detectors use magnets to locate metal in the walling material because the magnet is attracted to the metal.[9] The attraction grows stronger as the magnet gets closer to the metal in the walling. The strongest attraction point, if due to a metal fastener in the wall, should indicate the location of a stud, but careless wall construction can leave many metal fasteners off the studs or towards the edge, rendering the spot useless for anchoring objects. Magnetic stud detectors come in two types, stationary and moving.
Stationary magnetic detectors
Stationary magnet stud detectors use a small stationary magnet to detect the nails or screws placed into studs while putting up the walling material. The user must move the magnet around the wall until feeling the pull of magnetic attraction, and move in the direction of attraction. Since stationary magnetic stud detectors rely on the user to feel the attraction, they can be very erratic especially when the metal fasteners are located more deeply in the walling which decreases the overall attraction. When fasteners are deep or buried under thicker walling material (as in most plaster walls) the effectiveness of stationary magnets is considerably lower.
Moving magnetic detectors
Moving magnet stud detectors use a neodymium magnet that is suspended in an enclosure and free to move in response to hidden metal. The strength of this rare earth magnet and the easy movement of the magnet allow moving magnetic stud detectors to work on a broad range of construction types. The magnet is suspended in such a way that it always sits in its "home" position until it is moved directly over a metal fastener or metal stud. On walls with shallow fasteners, the magnet moves towards the wall with such velocity that it makes a distinct thud sound when it hits the wall. Because a moving magnet is not dependent on the operator to feel the attraction to the metal, fasteners buried more deeply under plaster or tile can be located with this detector. For deeper fasteners, the sound is softer since the speed of movement is slower.
Electronic stud finders
Electronic stud finders rely on sensors that detect changes in the dielectric constant of the wall.[10] The dielectric constant changes when the sensor is over a stud.[11] The lower reading indicates the presence of a stud in the wall. Internal capacitor stud finders can also come with other features that locate metal and live AC voltage.
Electronic stud finders currently come in three types: edge finders, center finders, and instant finders.
Edge finders
Edge finders are the most basic internal capacitor detectors.[12] Edge finders detect the edges of the stud or other material behind the walling. This finder must first be calibrated over an empty section of the wall, and then it can be moved along the wall until it senses a change in density, like at the edge of a stud. Edge finders should be moved from both directions to find both edges of the stud. The single sensor in edge finders can be prone to error, sometimes indicating a spot an inch or more from the stud’s edge. Once both edges have been marked, the user must determine the location of the stud’s center.
Center finders
Center stud finders detect the center of the stud by using two sensors that register separate readings of the wall’s dielectric constant.[13] When the two readings match, the finder indicates that it is centered on a stud. The several readings are used to determine the target center. Center finders only need to be moved from one direction. Like edge finders, center finders require calibration. Wall texturing can cause bumpy movement across the wall impairing the calibration readings.
Instant stud finders
Instant stud finders are a recent innovation.[14] Instant stud finders have multiple sensor plates, and do not need to be moved across the wall to detect a stud, overcoming the effects of bumpy wall texture. They use an algorithm to analyze the readings from the multiple sensor plates for a quicker, more accurate indication. Instant stud finders sense multiple regions of a wall simultaneously including the center of a stud, edges of the stud, and regions without studs. Instant stud finders will indicate varied widths of studs and the location of multiple studs at the same time.
Because the instant stud finders use multiple readings to determine the location of studs they are less vulnerable to construction anomalies (such as uneven paint, wall textures, wallpaper, uneven plaster, etc.) that can disorient center and edge finders.
References
- ↑ US patent 4099118
- ↑ Doug Mahoney. "Stud Finder for Home Use". 2016.
- ↑ Lee Wallender. "Stud Finders, Rated and Reviewed".
- ↑ Jon Eakes. "Tool Talk". quote: "We used to call them stud finders... DeWalt calls it a Radar Scanner, Bosch UWB Radar Technology and Milwaukee calls it a Sub Scanner detector. "
- ↑ Henry Fountain, ed. "The New York Times Circuits: How Electronic Things Work". 2001. p. 17. Reprinted from: Matt Lake. "How It Works: Detectors Can Find Just the Right Spot to Drive That Nail". 2001.
- ↑ Thomas E. McEwan. US 5457394 "Impulse radar studfinder." 1995.
- ↑ Thomas E. McEwan. Short range micro-power impulse radar with high resolution swept range gate 1998.
- ↑ "Radar Stud Finders - theBestStudFinder.com"
- ↑ "Magnetic Stud Finders - theBestStudFinder.com"
- ↑ http://electricstudfinder.com/how-do-stud-finders-work/
- ↑ http://home.howstuffworks.com/question271.htm
- ↑ "Edge Stud Finders - theBestStudFinder.com"
- ↑ "Center Stud Finders - theBestStudFinder.com"
- ↑ "Instant Stud Finders - theBestStudFinder.com"